Nimbus Water Systems MN-800-TF User Manual

Browse online or download User Manual for Water dispensers Nimbus Water Systems MN-800-TF. Nimbus Water Systems MN-800-TF User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
MN-800-TF
REVERSE OSMOSIS TREATMENT SYSTEM
OWNERS MANUAL
Nimbus Water Systems
41840 McAlby Court, Suite A
Murrieta, CA 92562-7036
800-451-9343
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - MN-800-TF

MN-800-TF REVERSE OSMOSIS TREATMENT SYSTEM OWNERS MANUAL Nimbus Water Systems 41840 McAlby Court, Suite A

Page 2

10 piece of black 5/8” tubing from the valve up to the 5/8” compression fitting at the back right side of the RO system manifold. §4.2.2 BY-PASS

Page 4

12 §5.0 SYSTEM FLUSH AND PERFORMANCE VERIFICATION Although MN-800-TF systems are fully tested at the factory prior to shipping, it is recommend

Page 5

13 • As a final check turn on the city water valve to the By-Pass Panel and check the plumbing for leaks. §5.2 PERFORMANCE VERIFICATION Factory t

Page 6

14 gauge reads about 60 psi (4.1 bar). Now, by opening the tank inlet valve the tank pressure should begin to drop and the system should turn on

Page 7

15 psi (1.4 bar). • Before servicing, always disconnect power to the unit to avoid shock. • To adjust, remove cover and refer to the diagram

Page 8

16 • Tag and disconnect the three tubing connections on the desalinator namely the feed, concentrate and product. • Unsnap the desalinator retain

Page 10

18 • Since the membrane is new it will need to be flushed and tested. Follow procedures outlined in §5.0 SYSTEM FLUSH AND PERFORMANCE VERIFICATI

Page 11

19 • Inspect sump for cracks. Replace as necessary. • Lubricate O-ring with an appropriate petroleum or silicone-based lubricant. Install O-rin

Page 12

2 THE NIMBUS MN-800 TF REVERSE OSMOSIS TREATMENT SYSTEM TABLE OF CONTENTS §1.0 MN-800 TF SYSTEM SPECIFICATIONS ...

Page 13

20 §8.0 PARTS AND ACCESSORIES ITEM PART NUMBER DESCRIPTION MOTORS & PUMPS 102612 Motor, ¾ HP 101168 Clamp, V Band 101199 P

Page 14

21 §9.0 ATTACHMENTS §9.1 REMOTE BYPASS SYSTEM INSTRUCTIONS Indication – When water is required even though RO product water of the desired quali

Page 15

22 §9.2 TDS MONITOR INSTRUCTIONS Model TDS-2B TDS Monitor Part # 100860 The Nimbus TDS-2B TDS Monitor is designed to operate within the Remote

Page 16

23 §9.3 WARRANTY Nimbus Water Systems Limited One Year Warranty Commercial and Industrial Systems The Nimbus Water Systems (Nimbus) Limited Wa

Page 18

3 THE NIMBUS MN-800 TF REVERSE OSMOSIS TREATMENT SYSTEM The Nimbus MN-800 TF is the perfect system for a wide variety of applications. Feature

Page 20 - ITEM

5 CONCENTRATE RECIRCULATION VALVE: A needle valve that controls the amount of concentrate from the desalinator array to be recirculated back into

Page 21

6 ANCILLARY EQUIPMENT: The following items are also covered in this manual to form a complete water treatment system. PRESSURE TANK: The tank pro

Page 22

7 §3.0 PRE-INSTALLATION PROCEDURES PLEASE READ CAREFULLY. FAILURE TO FOLLOW THESE PROCEDURES CAN RESULT IN DAMAGE TO YOUR SYSTEM AND VOID YOUR

Page 23 - §9.3 WARRANTY

8 §4.0 INSTALLATION PLEASE READ CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO FOLLOW THESE PROCEDURES CAN RESULT IN DAMAGE TO YOUR SYSTEM

Comments to this Manuals