18
•
Since the membrane is new it will need to be flushed and tested. Follow procedures
outlined in §5.0 SYSTEM FLUSH AND PERFORMANCE VERIFICATION.
§7.4 PRE FILTER CARBON CARTRIDGE REPLACEMENT
•
Before servicing, always disconnect power to the unit to avoid shock.
•
Close feed water and tank valves.
•
Activate the switch on the side of the gray box in the back of the unit just enough to relieve
any pressure in the filter.
•
Remove pre-filter sump by turning clockwise (as viewed from the top). A filter wrench may
be necessary.
•
Remove cartridge and inspect. If cartridge is extremely silted, you should consider
changing more often. Discard old cartridge.
•
Take O-ring from seat in sump and inspect for cracks or nicks, replace as necessary.
•
Inspect sump for cracks, especially in the threaded area. Replace as necessary.
•
Lubricate O-ring with an appropriate lubricant. Install O-ring into its seat in sump.
•
Install new sediment cartridge.
•
Replace sump by screwing it onto cap in a counter-clockwise direction (as viewed from
top). A wrench should not be needed. Hand tightened is sufficient.
•
Restore water and power; check for leaks.
§7.5 POST-FILTER CARBON CARTRIDGE REPLACEMENT
•
Before servicing, always disconnect power to the unit to avoid shock.
•
Close feed water and tank valves.
•
Open faucet or disconnect line from "FAUCET" connection to relieve pressure from the
carbon filter.
•
Remove post-filter sump by turning clockwise (as viewed from the top). A filter wrench
may be necessary.
•
Remove and discard old cartridge.
•
Remove O-ring from seat in sump and inspect for cracks or nicks, replace as necessary.
Comments to this Manuals