Since the membrane is new it will need to be flushed and tested. Follow procedures
outlined in §5.0 SYSTEM FLUSH AND PERFORMANCE VERIFICATION.
§7.4 PRE FILTER CARBON CARTRIDGE REPLACEMENT
Before servicing, always disconnect power to the unit to avoid shock.
Close feed water and tank valves.
Activate the switch on the side of the gray box in the back of the unit just enough to relieve
any pressure in the filter.
Remove pre-filter sump by turning clockwise (as viewed from the top). A filter wrench may
be necessary.
Remove cartridge and inspect. If cartridge is extremely silted, you should consider
changing more often. Discard old cartridge.
Take O-ring from seat in sump and inspect for cracks or nicks, replace as necessary.
Inspect sump for cracks, especially in the threaded area. Replace as necessary.
Lubricate O-ring with an appropriate lubricant. Install O-ring into its seat in sump.
Install new sediment cartridge.
Replace sump by screwing it onto cap in a counter-clockwise direction (as viewed from
top). A wrench should not be needed. Hand tightened is sufficient.
Restore water and power; check for leaks.
§7.5 POST-FILTER CARBON CARTRIDGE REPLACEMENT
Before servicing, always disconnect power to the unit to avoid shock.
Close feed water and tank valves.
Open faucet or disconnect line from "FAUCET" connection to relieve pressure from the
carbon filter.
Remove post-filter sump by turning clockwise (as viewed from the top). A filter wrench
may be necessary.
Remove and discard old cartridge.
Remove O-ring from seat in sump and inspect for cracks or nicks, replace as necessary.