Tag and disconnect the three tubing connections on the desalinator namely the feed,
concentrate and product.
Unsnap the desalinator retainers and pull desalinator(s) out.
Remove retaining clips from ends of desalinator by tapping the open ends of the clips with
a plastic or rawhide mallet until they are through the slots in the pressure vessel. Pull
clips completely out of pressure vessel.
Remove end plugs by gently pulling on the fittings. Do not use pliers on the fitting threads
because the threads might get damaged. As a suggestion, attach a scrap piece of tubing
(with a nut, a ferrule and an insert), and then use the tubing as a handle. See §8.0
PARTS & ACCESSORIES for end plug pulling tool.
Push membrane out of pressure vessel from the feed end.
Discard old membrane. Be careful not to discard the gray closed-end plug or the product
inter-connector.
Clean vessel and plugs with a mild detergent soap and rinse thoroughly.
Inspect all O-rings for cracks or nicks, replace as necessary. Lubricate O-rings with an
appropriate petroleum or silicone-based lubricant.
Install new membrane into the feed end of vessel (in the direction shown in Figure 4). Be
sure to note the end with the brine seal.
Install closed-end plug into vessel feed end plug, and product inter-connector into the
vessel concentrate/product end plug.
Install end plugs into their proper ends. IF END PLUGS ARE INSTALLED ON THE
WRONG ENDS THE SYSTEM WILL NOT OPERATE PROPERLY.
Install retaining clips and mount desalinator onto frame using tabs and install the retaining
clips.
Connect feed, concentrate, and product lines to their proper ports.